playground:startup [2023/09/07 04:14]
carter
playground:startup [2023/09/07 04:21]
carter
Line 63: Line 63:
 **4. Beam Transport** **4. Beam Transport**
  
-a.      Use the magnet predictor tool and set Quad 1 to the predicted value.+a.      Use the magnet predictor tool and set Quad 1 to the predicted value.  Do not make large abrupt changes to the Quad 1 current. ​ If a large abrupt change in current is attempted, the power supply may begin oscillating. ​ To stop this oscillation,​ run the current slider to zero then re-adjust to the desired current at a slower non-abrupt rate
  
 b. Tune beam and send it around the properly configured Analyzing Magnet. ​ b. Tune beam and send it around the properly configured Analyzing Magnet. ​