Line 30: Line 30:
 a.  Switch the POWER SUPPLIES to ON, the yellow light should come on. Switch CHAIN MOTORS to ON, lights 1, 2, and 3 should all come on.  Begin to increase the CHARGING VOLTAGE ​ while observing the TERMINAL VOLTAGE and the GRID VOLTAGE. ​ DO NOT allow the GRID VOLTAGE to become more negative than   -10 VDC.  ​ a.  Switch the POWER SUPPLIES to ON, the yellow light should come on. Switch CHAIN MOTORS to ON, lights 1, 2, and 3 should all come on.  Begin to increase the CHARGING VOLTAGE ​ while observing the TERMINAL VOLTAGE and the GRID VOLTAGE. ​ DO NOT allow the GRID VOLTAGE to become more negative than   -10 VDC.  ​
  
-b. Continue to increase the CHARGING VOLTAGE until you reach the approximate TERMINAL VOLTAGE **__OR__** until the GRID VOLTAGE reaches ​ -10 VDC, **__THEN__** proceed to step 2:+b. Continue to increase the CHARGING VOLTAGE until you reach the approximate TERMINAL VOLTAGE **__OR__** until the GRID VOLTAGE reaches ​ -10 VDC, **__THEN__** proceed to step 2:     (The GRID VOLTAGE may never reach -10 VDC when running at ultra low Terminal energy, E < 0.300 MV, do the best you can)
  
  