 ====== Accelerator Start-up ====== ====== Accelerator Start-up ======
  
-1. **Initial Machine Voltage setup:**+1. **Verify ​Initial Machine Voltage setup:**
  
 Initial conditions on TPS: Initial conditions on TPS:
Line 30: Line 30:
 a.  Switch the POWER SUPPLIES to ON, the yellow light should come on. Switch CHAIN MOTORS to ON, lights 1, 2, and 3 should all come on.  Begin to increase the CHARGING VOLTAGE ​ while observing the TERMINAL VOLTAGE and the GRID VOLTAGE. ​ DO NOT allow the GRID VOLTAGE to become more negative than   -10 VDC.  ​ a.  Switch the POWER SUPPLIES to ON, the yellow light should come on. Switch CHAIN MOTORS to ON, lights 1, 2, and 3 should all come on.  Begin to increase the CHARGING VOLTAGE ​ while observing the TERMINAL VOLTAGE and the GRID VOLTAGE. ​ DO NOT allow the GRID VOLTAGE to become more negative than   -10 VDC.  ​
  
-b. Continue to increase the CHARGING VOLTAGE until you reach the approximate TERMINAL VOLTAGE **__OR__** until the GRID VOLTAGE reaches ​ -10 VDC, **__THEN__** proceed to step 2:+b. Continue to increase the CHARGING VOLTAGE until you reach the approximate TERMINAL VOLTAGE **__OR__** until the GRID VOLTAGE reaches ​ -10 VDC, **__THEN__** proceed to step 2:     (The GRID VOLTAGE may never reach -10 VDC when running at ultra low Terminal energy, E < 0.300 MV, do the best you can)
  
  
Line 58: Line 58:
 **4. Beam Transport** **4. Beam Transport**
  
-a. Tune beam and send it around ​the properly configured Analyzing Magnet+a.      Use the magnet predictor tool and set Quad 1 to the predicted value.
  
-b. You may need to make adjustments to the TERMINAL VOLTAGE dial to get the terminal to the proper energy for transmission ​around the magnet and fairly balanced current on the slits+b. Tune beam and send it around the properly configured Analyzing Magnet
  
-c. When current is present on the LE and HE Slit current meters you may then switch ​the Control Mode to AUTO (middle position) and the SLIT control light should illuminate. ​ If there is instability in slit control you may try raising ​the CONTROL GAIN more.+c. You may need to make adjustments to the TERMINAL VOLTAGE dial to get the terminal to the proper energy for transmission around the magnet and fairly balanced current on the slits
  
-d. When in AUTO control the machine will go back to GVM control anytime the beam is interrupted.+d. When current is present on the LE and HE Slit current meters you may then switch the Control Mode to AUTO (middle position) and the SLIT control light should illuminate. ​ If there is instability in slit control you may try raising the CONTROL GAIN more.  If the slit currents are not balanced when in slit control, make slight adjustments in the CHARGING VOLTAGE to balance the slit currents. 
 + 
 +e. When in AUTO control the machine will go back to GVM control anytime the beam is interrupted.
  
playground/startup.txt · Last modified: 2024/04/05 04:25 by carter