This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Last revision Both sides next revision | ||
playground:shutdown [2012/02/01 11:06] 132.235.40.113 |
playground:shutdown [2012/06/01 10:30] carter |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ==== Machine Shut-down with TPS Controller ==== | + | ==== Accelerator Shutdown ==== |
1. Switch OVERVOLTAGE PROTECTION to DISABLE. | 1. Switch OVERVOLTAGE PROTECTION to DISABLE. | ||
Line 5: | Line 5: | ||
2. Switch the control mode to GVM. | 2. Switch the control mode to GVM. | ||
- | 3. Turn the CONTROL GAIN to zero. | + | 3. Slowly turn the CONTROL GAIN to zero while watching the grid voltage. If the grid voltage rises above 10 volts, reduce the CHARGING VOLTAGE to keep the grid voltage less than 10 volts, then continue reducing the CONTROL GAIN to zero. |
4. Turn the CHARGING VOLTAGE dial down to 0.10 | 4. Turn the CHARGING VOLTAGE dial down to 0.10 |