User Tools

Site Tools


playground:shutdown

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
playground:shutdown [2009/04/15 15:30]
odonnell Change to wiki numbering format; added line about not letting the corona points go negative.
playground:shutdown [2012/06/01 10:30]
carter
Line 1: Line 1:
-==== Machine ​Shutdown ====+==== Accelerator ​Shutdown ====
  
-** Machine Shutdown **+1. Switch OVERVOLTAGE PROTECTION to DISABLE.
  
-   - Log Machine settings, log radiation monitor tape if necessary. +2. Switch ​the control mode to GVM. 
-   ​- ​Switch ​stabilizer ​to "​AUTO"​ + 
-   - Put cup in -- when putting in L.E.  ​cup at high terminal ​voltage ​be prepared ​to run belt charge down as terminal ​voltage ​will increase when the beam loading is removed+3. Slowly turn the CONTROL GAIN to zero while watching the grid voltage.  ​If the grid voltage ​rises above 10 volts, reduce the CHARGING VOLTAGE ​to keep the grid voltage ​less than 10 volts, then continue reducing ​the CONTROL GAIN to zero
-   - Switch stabilizer to "​STANDBY"​. + 
-   - Turn "​GRIDDED ​VOLTAGE ​TUBE LENS" ​down. +4. Turn the CHARGING ​VOLTAGE ​dial down to 0.10 
-   - Monitor corona current while changing belt charge; do not run in (extend) the corona points when the terminal charge may become negative (i.e. with the plastic belt). ​ Reverse current will damage the stabilizer circuit. ​ + 
-   - Run belt charge down  +5. Switch CHAIN MOTORS to OFF. 
-   - Turn belt charge "OFF"+ 
-   - Turn drive motor "​OFF"​. +6. Switch POWER SUPPLIES ​to OFF. 
-   - Start Source shut down (all control room operations). + 
-   - Set steerers to zero and then to "OFF"+7. Turn the TERMINAL VOLTAGE dial to zero.
-   - Run magnets and quadrupole lenses down (coarse to zero, fine to 500), then turn off (push the "​power"​ button). +
-   ​- ​Turn the beam profile monitor (BPM) to "​OFF"​ +
-   - Turn buncher and chopper power to "​OFF"​. +
-   - Complete control room source shutdown and run low energy extension einzel lenses down. +
-   - //(Only for maintenance shutdown)// Switch stabilizer to "​OFF"​. +
-   - //(Only for maintenance shutdown)// Turn key switch "​OFF"​. +
-   - Complete source shut down in vault.+
  
  
playground/shutdown.txt · Last modified: 2017/04/17 11:45 by jacobs