User Tools

Site Tools


playground:shutdown

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
playground:shutdown [2009/04/15 15:30]
odonnell Change to wiki numbering format; added line about not letting the corona points go negative.
playground:shutdown [2012/02/01 11:06]
132.235.40.113
Line 1: Line 1:
-==== Machine ​Shutdown ​====+==== Machine ​Shut-down with TPS Controller ​====
  
-** Machine Shutdown **+1. Switch OVERVOLTAGE PROTECTION to DISABLE.
  
-   - Log Machine settings, log radiation monitor tape if necessary. +2. Switch the control mode to GVM
-   ​- ​Switch ​stabilizer to "​AUTO"​ + 
-   - Put cup in -- when putting in L.E.  cup at high terminal voltage be prepared to run belt charge down as terminal voltage will increase when the beam loading is removed. +3. Turn the CONTROL GAIN to zero
-   - Switch stabilizer ​to "​STANDBY"​+ 
-   - Turn "​GRIDDED VOLTAGE TUBE LENS" down. +4. Turn ​the CHARGING VOLTAGE dial down to 0.10 
-   - Monitor corona current while changing belt charge; do not run in (extend) the corona points when the terminal charge may become negative (i.e. with the plastic belt). ​ Reverse current will damage the stabilizer circuit.  + 
-   - Run belt charge down.  ​ +5. Switch CHAIN MOTORS ​to OFF. 
-   - Turn belt charge "​OFF"​. + 
-   ​- ​Turn drive motor "​OFF"​. +6. Switch ​POWER SUPPLIES ​to OFF. 
-   - Start Source shut down (all control room operations). + 
-   - Set steerers ​to zero and then to "​OFF"​+7. Turn the TERMINAL VOLTAGE dial to zero.
-   - Run magnets and quadrupole lenses down (coarse to zero, fine to 500), then turn off (push the "​power"​ button). +
-   - Turn the beam profile monitor (BPM) to "OFF+
-   - Turn buncher and chopper power to "​OFF"​+
-   - Complete control room source shutdown and run low energy extension einzel lenses down. +
-   - //(Only for maintenance shutdown)// ​Switch ​stabilizer ​to "OFF"+
-   - //(Only for maintenance shutdown)// ​Turn key switch "​OFF"​. +
-   - Complete source shut down in vault.+
  
  
playground/shutdown.txt · Last modified: 2017/04/17 11:45 by jacobs