User Tools

Site Tools


playground:power

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
playground:power [2018/01/12 15:03]
jacobs
playground:power [2020/07/12 13:42]
carter
Line 19: Line 19:
 4) If the blink was more than a few milliseconds the accelerator and all electrostatic devices will have shut down and all electrically operated gate valves (except for the sources) will have closed. ​ If the accelerator was running, set all of its controls to the initial condition (off) settings.  ​ 4) If the blink was more than a few milliseconds the accelerator and all electrostatic devices will have shut down and all electrically operated gate valves (except for the sources) will have closed. ​ If the accelerator was running, set all of its controls to the initial condition (off) settings.  ​
  
-5)      Check the “main loop temp” on the alarm panel. ​ If it is greater than ~58 the chiller has failed and you will need staff to restart it.  Turn down the magnets. +5)      Check the “main loop temp” on the alarm panel. ​ If it is greater than ~58 the chiller has failed and you will need staff to restart it.  ​Check the status of the magnets. Each magnet control module should be showing a red light for standby or off condition. Magnet current meters need to be showing zero amps. Turn down the magnets ​if they are not at zero.      ​
- +
-6)      +
  
 6) Return to the vault and check that the 4 cryopumps ( LE line, LE pumping station, HE pumping station, analyzer line) are still cold.  All pumps have reliable temperature gauges. ​ Condensation or frost on the cryopump is a sign of failure. ​ If they appear to still be good open the "​pump"​ gate valve at each pumping station. ​ If they have failed, shut down the compressor to begin regeneration,​ do not open any gate valves. Shut down by the yellow breaker on the rear of the compressor. 6) Return to the vault and check that the 4 cryopumps ( LE line, LE pumping station, HE pumping station, analyzer line) are still cold.  All pumps have reliable temperature gauges. ​ Condensation or frost on the cryopump is a sign of failure. ​ If they appear to still be good open the "​pump"​ gate valve at each pumping station. ​ If they have failed, shut down the compressor to begin regeneration,​ do not open any gate valves. Shut down by the yellow breaker on the rear of the compressor.
Line 28: Line 26:
    
  
-8) This process has preserved the vacuum, cooling, climate control systems. ​ The ion gauges, gates valves and ion sources will need to be carefully re-started to resume ​operations.  Call the lab staff personnel for assistance in these matters.+8) This process has preserved the vacuum, cooling, climate control systems. ​ The ion gauges, gates valves and ion sources will need to be carefully re-started to resume ​operation. ​ To restore to the console control-power (cups, steerers, chain drive etc. you will have to go to the blue chain drive control box in the vault and press the "​start"​ button.  Call the lab staff personnel for assistance in these matters.
  
playground/power.txt · Last modified: 2020/07/12 13:43 by carter