Line 6: | Line 6: | ||
- You may have to adjust the VERTICAL POSITION control to find the horizontal line. | - You may have to adjust the VERTICAL POSITION control to find the horizontal line. | ||
- Set the HORIZONTAL SWEEP to 60. | - Set the HORIZONTAL SWEEP to 60. | ||
- | - Recycle the analyzing magnet if needed. This is done using the RECYCLE button on the analyzing magnet control window. | + | - Recycle the analyzing magnet if needed. This is done using the RECYCLE button on the analyzing magnet control window(NumLock must be off). |
- Set the analyzing magnet power supply to a current slightly lower than the current predicted for this energy. | - Set the analyzing magnet power supply to a current slightly lower than the current predicted for this energy. | ||
- | - Set the TUNING VERNIER control to about mid range on its 10 turn control. Rotate counterclockwise until stop then 5 turns clockwise. | + | - Set the TUNING VERNIER control to about mid range on its 10 turn control. Rotate counterclockwise until it stops then rotate 5 turns clockwise. |
- Select a frequency about 1% less than the frequency desired for the beam energy. | - Select a frequency about 1% less than the frequency desired for the beam energy. | ||
- In the light yellow (Tandem) window type the command "nmrgoto 1234.567" where 1234.567 is the frequency calculated in the previous step. | - In the light yellow (Tandem) window type the command "nmrgoto 1234.567" where 1234.567 is the frequency calculated in the previous step. |