User Tools

Site Tools


playground:interlock

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
Next revision Both sides next revision
playground:interlock [2012/02/07 15:26]
132.235.40.1 created
playground:interlock [2012/02/15 19:10]
odonnell Indent bypass instructions & number them
Line 1: Line 1:
 +**Interlock Rules**
 +
 +
 +  - A safety interlock shall not be used to turn off the Accelerator and/or beam, except in an emergency, or when testing the safety interlock. ​ Routine shutdown shall be done following normal operating procedures and normal controls.
   - No Operator will intentionally bypass a safety interlock.   - No Operator will intentionally bypass a safety interlock.
-  - Discovery of a failed safety interlock will suspend all operations until that failure can be repaired.+  - Discovery of a failed safety interlock ​or warning device ​will suspend all operations until that failure can be repaired.
   - If, for any reason, the TALC finds it necessary to intentionally bypass a safety interlock this action shall be:   - If, for any reason, the TALC finds it necessary to intentionally bypass a safety interlock this action shall be:
-  * Authorized by the OU Radiation Safety Officer; +    - Authorized by the OU Radiation Safety Officer 
-  ​* ​Recorded in the Electronic Logbook and emailed to all recipients; +    ​- ​Recorded in the Electronic Logbook and emailed to all recipients 
-  ​* ​Posted as a written notice at the Accelerator Control Consoleand +    ​- ​Posted as a written notice at the Accelerator Control Consoleand 
-  ​* ​Terminated as soon as possible.+    ​- ​Terminated as soon as possible. 
  
playground/interlock.txt · Last modified: 2012/03/05 13:18 by jacobs