   * a.  The digital display reads out the total integrated charge in Coulombs * Multiplier (including the decimal point). ​ The pre-scaler value (h) is automatically included in the display by moving the decimal point in the display readout. ​ For example, if the digital display reads 1234.56 and the range is 10**-6 the charge is 1234.56 uC.   * a.  The digital display reads out the total integrated charge in Coulombs * Multiplier (including the decimal point). ​ The pre-scaler value (h) is automatically included in the display by moving the decimal point in the display readout. ​ For example, if the digital display reads 1234.56 and the range is 10**-6 the charge is 1234.56 uC.
 +
   * b.  This switch sets the 10**-X range value.   * b.  This switch sets the 10**-X range value.
 +
   * c.  This is the instantaneous beam current value. ​ Full scale is the 1.0 * 10**(range switch) Amps full scale.   * c.  This is the instantaneous beam current value. ​ Full scale is the 1.0 * 10**(range switch) Amps full scale.
 +
   * d.  This switch is used to expand the full scale indication of the beam current on the meter only.  It has no effect on the total integrated charge value.   * d.  This switch is used to expand the full scale indication of the beam current on the meter only.  It has no effect on the total integrated charge value.
   * e.  This switch selects the polarity of the input current.   * e.  This switch selects the polarity of the input current.
Line 21: Line 24:
   * p.  This switch when up will reset the Beam Current Integrator to 0 if the Reset Enable switch (o.) is up.  No integration will take place until this switch is down.  The external reset BNC will reset the Beam Current Integrator when a +5 volt level is applied to the external reset input AND the Reset Enable (o.) switch is up.   * p.  This switch when up will reset the Beam Current Integrator to 0 if the Reset Enable switch (o.) is up.  No integration will take place until this switch is down.  The external reset BNC will reset the Beam Current Integrator when a +5 volt level is applied to the external reset input AND the Reset Enable (o.) switch is up.
   * q.  This switch will allow the Level Discriminators (j. and n.)to control the integrator when the switch is in the UP position.   * q.  This switch will allow the Level Discriminators (j. and n.)to control the integrator when the switch is in the UP position.
-  * r.  The Percent 0-100 meter reads BCI dead time in the DT (up) position and Beam Fluctuation (BF) in the down position. ​+  * r.  The Percent 0-100 meter reads BCI dead time in the DT (up) position and Beam Fluctuation (BF) in the down position
 +  * s.  This is a SPARE (unused) switch. 
 +  * t.  Fast (F) / Slow (S) meter response. ​ This switch will allow averaging the indicated beam current for unsteady beams. 
 +  * u.  This is a SPARE (unused) switch. 
 +  * w.  Preset Charge (Enable Disable). ​ This switch will allow stopping the integration and providing a control output level (Integrate Control Output) when the integrated charge display matches the digits in the 6 thumbwheel Preset (i.) switches when in the Enable position. ​ When in the Disable position, integration will not stop if the switches match and the digital diaplay will wrap around from 999999 to 000000.
  
  
   * {{bci.pdf|Beam Current Integrator writeup by designer, Bob Young}}   * {{bci.pdf|Beam Current Integrator writeup by designer, Bob Young}}