User Tools

Site Tools


playground:alphatross

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
playground:alphatross [2022/01/31 11:57]
leblanc Typos
playground:alphatross [2022/06/08 09:05] (current)
leblanc Same as last revision, which didn't have any changes.
Line 16: Line 16:
 == In the Control Room == == In the Control Room ==
  
-  - Source camera must have a view of the faraday ​screen on the blue box of the source head.  ​+  - Source camera must have a view of the Faraday ​screen on the blue box of the source head.  ​
     - To gain control of the source camera: On the joystick unit press "​2"​ then "​CAM"​ to specify the camera.     - To gain control of the source camera: On the joystick unit press "​2"​ then "​CAM"​ to specify the camera.
-    - Use the joystick and "​TELE"​ or "​WIDE"​ to create a view of interest.+    - Use the joystick and "​TELE"​ or "​WIDE"​ to create a view of interest. Pressing "​6"​ followed by "​Call"​ will move and zoom the camera appropriately
   - If not already present, launch the Alphatross software (Version 6.0) on the source computer.   - If not already present, launch the Alphatross software (Version 6.0) on the source computer.
   - Press the "​on"​ button for Water Cooling. ​ The water cooling system:   - Press the "​on"​ button for Water Cooling. ​ The water cooling system:
Line 45: Line 45:
         - Source is still grounded.         - Source is still grounded.
         - Source is dirty and requires service.         - Source is dirty and requires service.
-    - Set Extractor Voltage to 5kV. 
-    - Set Bias Voltage to a value that gives desired injection energy. ​ Typical values are at least 53keV. 
-      - Injection energy is displayed in the upper window. 
-      - Injection energy is the sum of Probe, Extractor, and Bias voltages. 
-      - Beam yields improve above 30 keV. 
-    - Set the Focus Voltage to 5.5 kV 
-    - Set the Faraday cup meter to position 7 (alphatross cup). 
-    - Tune for maximum __stable__ beam. 
-      - Primary adjustment at this stage seems to be focus voltage. 
-      - Current may be on the order of 30 μA. 
- 
-==**DO NOT PROCEED UNTIL CHAMBER TEMPERATURE EXCEEDS 39°C**== 
- 
   - Set the Oven Voltage to 80 V.   - Set the Oven Voltage to 80 V.
 +  - Set Extractor Voltage to 5kV.
 +  - Set Bias Voltage to a value that gives desired injection energy. ​ Typical values are at least 53keV.
 +    - Injection energy is displayed in the upper window.
 +    - Injection energy is the sum of Probe, Extractor, and Bias voltages.
 +    - Beam yields improve above 30 keV.
 +  - Set the Focus Voltage to 5.5 kV
 +  - Set the Faraday cup meter to position 7 (Alphatross cup).
 +  - Tune for maximum __stable__ beam.
 +    - Primary adjustment at this stage seems to be focus voltage.
 +    - Current may be on the order of 30 μA.
   - Set Einzel Lens to 20 kV.   - Set Einzel Lens to 20 kV.
   - Wait until the Oven Temperature is at least 160 C, 10 - 20 minutes.   - Wait until the Oven Temperature is at least 160 C, 10 - 20 minutes.
playground/alphatross.1643648267.txt.gz · Last modified: 2022/01/31 11:57 by leblanc