playground:alphatross [2022/01/31 11:57]
leblanc Typos
playground:alphatross [2022/06/03 11:36]
leblanc Remove waiting step, add camera position, fix capitalization.
Line 16: Line 16:
 == In the Control Room == == In the Control Room ==
  
-  - Source camera must have a view of the faraday ​screen on the blue box of the source head.  ​+  - Source camera must have a view of the Faraday ​screen on the blue box of the source head.  ​
     - To gain control of the source camera: On the joystick unit press "​2"​ then "​CAM"​ to specify the camera.     - To gain control of the source camera: On the joystick unit press "​2"​ then "​CAM"​ to specify the camera.
-    - Use the joystick and "​TELE"​ or "​WIDE"​ to create a view of interest.+    - Use the joystick and "​TELE"​ or "​WIDE"​ to create a view of interest. Pressing "​6"​ followed by "​Call"​ will move and zoom the camera appropriately
   - If not already present, launch the Alphatross software (Version 6.0) on the source computer.   - If not already present, launch the Alphatross software (Version 6.0) on the source computer.
   - Press the "​on"​ button for Water Cooling. ​ The water cooling system:   - Press the "​on"​ button for Water Cooling. ​ The water cooling system:
Line 45: Line 45:
         - Source is still grounded.         - Source is still grounded.
         - Source is dirty and requires service.         - Source is dirty and requires service.
-    ​- Set Extractor Voltage to 5kV. +  ​- Set Extractor Voltage to 5kV. 
-    - Set Bias Voltage to a value that gives desired injection energy. ​ Typical values are at least 53keV. +  - Set Bias Voltage to a value that gives desired injection energy. ​ Typical values are at least 53keV. 
-      - Injection energy is displayed in the upper window. +    - Injection energy is displayed in the upper window. 
-      - Injection energy is the sum of Probe, Extractor, and Bias voltages. +    - Injection energy is the sum of Probe, Extractor, and Bias voltages. 
-      - Beam yields improve above 30 keV. +    - Beam yields improve above 30 keV. 
-    - Set the Focus Voltage to 5.5 kV +  - Set the Focus Voltage to 5.5 kV 
-    - Set the Faraday cup meter to position 7 (alphatross ​cup). +  - Set the Faraday cup meter to position 7 (Alphatross ​cup). 
-    - Tune for maximum __stable__ beam. +  - Tune for maximum __stable__ beam. 
-      - Primary adjustment at this stage seems to be focus voltage. +    - Primary adjustment at this stage seems to be focus voltage. 
-      - Current may be on the order of 30 μA. +    - Current may be on the order of 30 μA.
- +
-==**DO NOT PROCEED UNTIL CHAMBER TEMPERATURE EXCEEDS 39°C**== +
   - Set the Oven Voltage to 80 V.   - Set the Oven Voltage to 80 V.
   - Set Einzel Lens to 20 kV.   - Set Einzel Lens to 20 kV.
playground/alphatross.txt · Last modified: 2022/06/08 09:05 by leblanc