**Faraday Cups** [[http://en.wikipedia.org/wiki/Faraday_cup|Wikipedia description of a Faraday Cup]] [[OUAL Faraday Cup Control Panel Photograph]] * Each cup is contolled by one of the push buttons in the photo. - The name of the cup operated by the button is always illuminated. - When the cup is in, the red "in" light in the button is illuminated. - When the cup is out, the green "out" light in the button is illuminated. - Each time a button is pushed the cup will change to the other state, in or out. * Placing the LE cup in the "out" position will sound an audible and visual warning throughout the facility. * When the HIGH RAD MODE key switch is in the "ON" position there will be a 15 second delay between pushing the LE cup "out" button and: - The cup lifting out of the beam path - The green "out" light on the button illuminating * We have 4 Faraday Cups for beam current optimization at critical points along the beam path. - LE: Located after the Buncher Tubes and before the LE XY steerer. - HE: Located at the exit of the Accelerator before Quad 1. - Analyzer: Located after the Image Slits and before the Beam Pick Off. - Swinger: Located under the steps, after the Analyzer and before Swinger Magnet 1.