This shows you the differences between two versions of the page.
Next revision | Previous revision Next revision Both sides next revision | ||
start [2016/05/12 14:59] jacobs [Tritium Emergency] |
start [2020/07/22 11:10] carter |
||
---|---|---|---|
Line 11: | Line 11: | ||
* [[playground:shift|Shift Change Procedure]] | * [[playground:shift|Shift Change Procedure]] | ||
+ | * [[http://apps.brownbearsw.com/iobee/OUAL/showview/-Default-|Update Lab IN/OUT Board]] | ||
Line 32: | Line 33: | ||
===== General Safe Operating Procedures ===== | ===== General Safe Operating Procedures ===== | ||
- | * [[http://www.ohio.edu/riskandsafety/radiationsafety/rad_saf_handbook.htm#Htoc|See Sections III, IV, V, VI, and IX of the Radiation Safety Handbook]] | + | * [[https://www.ohio.edu/facilities/safety/radiation-safety/rad-saf-handbook|See Sections III, IV, V, VI, and IX of the Radiation Safety Handbook]] |
===== Source Instructions ===== | ===== Source Instructions ===== | ||
- | * [[playground:alpha|Alpha Source]] | + | * [[playground:alphatross|Alpha Source]] |
* [[playground:sputter|Sputter Source]] | * [[playground:sputter|Sputter Source]] | ||
* [[sputter:pellet|Sputter Source Target Pellet Change]] | * [[sputter:pellet|Sputter Source Target Pellet Change]] | ||
+ | * [[playground:alpha|Old HVEC Alpha Source]] | ||
Line 74: | Line 76: | ||
- | * {{inflection.pdf|Inflection Magnet Curve (AMU*KeV vs. AMPs)}} | + | * {{inflectioncal.pdf|Inflection Magnet Curve (AMU*KeV vs. AMPs)}} |
* {{buncher_tables.pdf|Buncher/Extractor Tables}} | * {{buncher_tables.pdf|Buncher/Extractor Tables}} | ||
* {{charge exchange.pdf|Charge State Yield Tables}} | * {{charge exchange.pdf|Charge State Yield Tables}} | ||
Line 88: | Line 90: | ||
* [[playground:swinger|Swinger Operations]] | * [[playground:swinger|Swinger Operations]] | ||
+ | * [[https://inpp.ohio.edu/~daqlinux/index.html|DAQ instructions www.daqlinux.com]] | ||
+ | ===== Tritium Operations ===== | ||
+ | * {{:playground:tritiumsop.pdf|Tritium SOP}} | ||
===== Facility Shutdown ===== | ===== Facility Shutdown ===== | ||
Line 108: | Line 113: | ||
* [[playground:vesda|VESDA]] | * [[playground:vesda|VESDA]] | ||
+ | ===== Emergency Responder Access ===== | ||
+ | * {{emergency_entry_sop.pdf|Emergency Response Access SOP}} | ||
===== Power Failures ===== | ===== Power Failures ===== | ||
- | * [[playground:power|Short Interuption (<1 min)]] | + | * [[playground:power|Short Interuption (<3 min)]] |
- | * [[playground:powerout|Long Interuption ( >1 min)]] | + | * [[playground:powerout|Long Interuption ( >3 min)]] |
===== Chemical & Radiation Emergencies ===== | ===== Chemical & Radiation Emergencies ===== | ||
- | * [[http://www.ohio.edu/riskandsafety/radiationsafety/rad_saf_handbook.htm#Htoc|See Section VIII of the Radiation Safety Handbook]] | + | * [[https://www.ohio.edu/facilities/safety/radiation-safety/rad-saf-handbook|See Section VIII of the Radiation Safety Handbook]] |
===== Tritium Emergency ===== | ===== Tritium Emergency ===== | ||
- | * [[https://www.ohio.edu/riskandsafety/docs/RadManual/RadManAppendix24.pdf|Radiation Safety Handbook, Appendix 24: Tritium Gas Cells]] | + | * [[https://www.ohio.edu/sites/default/files/sites/facilities/RadManAppendix24.pdf|Radiation Safety Handbook, Appendix 24: Tritium Gas Cells]] |
* [[playground:tritium_emergency|Tritium Emergency Procedure]] (local copy, use RSH above as definitive copy) | * [[playground:tritium_emergency|Tritium Emergency Procedure]] (local copy, use RSH above as definitive copy) | ||
| | ||
Line 158: | Line 165: | ||
===== Ohio Administrative Code and OUAL Compliance Statements ===== | ===== Ohio Administrative Code and OUAL Compliance Statements ===== | ||
- | * [[http://www.odh.ohio.gov/~/media/ODH/ASSETS/Files/rules/final/3701_1/37011-68/37011-68-05f.ashx|OAC 3701:1-68-05 Industrial Particle Accelerators]] | + | * [[http://codes.ohio.gov/oac/3701:1-68-02|OAC 3701:1-68-02 General requirements]] |
- | * [[http://www.odh.ohio.gov/~/media/ODH/ASSETS/Files/rules/final/3701_1/37011-68/37011-68-05-apdx.ashx|OAC 3701:1-68-05 Appendix A]] | + | * [[http://codes.ohio.gov/oac/3701:1-68-05v1|OAC 3701:1-68-05 Non-medical particle accelerator systems]] |
* [[playground:compliance|OUAL Compliance Statements]] | * [[playground:compliance|OUAL Compliance Statements]] | ||
- | *[[http://www.odh.ohio.gov/rules/final/37011/37011-38.aspx|OAC 3701:1-38 General Radiation Protection Standards for Sources of Radiation]] | + | *[[http://codes.ohio.gov/oac/3701%3A1-38|OAC 3701:1-38 General Radiation Protection Standards for Sources of Radiation]] |
Line 180: | Line 187: | ||
===== Key Holder Training Flow ===== | ===== Key Holder Training Flow ===== | ||
- | * {{key_holder_training_flow.pdf|Checklist}} | + | * {{key_holder_training_flow_new.pdf|Checklist}} |
Line 194: | Line 201: | ||
+ | ===== Operator Training Web Pages ===== | ||
+ | |||
+ | |||
+ | |||
+ | *[[https://inpp.ohio.edu/~oual/operators/operators.php]] | ||
Line 241: | Line 253: | ||
- | ===== Operator Training Web Pages ===== | + | ===== Videos ===== |
- | *[[https://edwards1.phy.ohiou.edu/~oual/operators/training/optrain.php]] | + | * [[https://inpp.ohio.edu/~carter/Levels_of_vacuum.mp4|Levels of Vacuum]] |