User Tools

Site Tools


start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
start [2012/12/06 10:20]
carter
start [2018/12/20 07:16]
carter [Beam Operations]
Line 49: Line 49:
  * [[playground:​trip|Over Voltage Trip]]  * [[playground:​trip|Over Voltage Trip]]
   * [[playground:​spark|Spark Instructions]]   * [[playground:​spark|Spark Instructions]]
 +
 +
 +
  
  
Line 73: Line 76:
   * {{inflection.pdf|Inflection Magnet Curve (AMU*KeV vs. AMPs)}}   * {{inflection.pdf|Inflection Magnet Curve (AMU*KeV vs. AMPs)}}
   * {{buncher_tables.pdf|Buncher/​Extractor Tables}}   * {{buncher_tables.pdf|Buncher/​Extractor Tables}}
 +  * {{charge exchange.pdf|Charge State Yield Tables}}
  * [[playground:​pulsing|Pulsing and Bunching]]  * [[playground:​pulsing|Pulsing and Bunching]]
   * [[playground:​quadControls|Computer Control of Quadrupoles]]   * [[playground:​quadControls|Computer Control of Quadrupoles]]
Line 78: Line 82:
   * [[playground:​nmr|NMR Setup]]   * [[playground:​nmr|NMR Setup]]
   * [[playground:​integrator|Beam Current Integrator]]   * [[playground:​integrator|Beam Current Integrator]]
 +  * [[playground:​45R|Venting/​Shutdown/​Regenerate the 45R Beam Line]]
   * Beam Energy: ​ E = Terminal(charge state + 1) + injection energy   * Beam Energy: ​ E = Terminal(charge state + 1) + injection energy
  
Line 84: Line 88:
   * [[playground:​swinger|Swinger Operations]]   * [[playground:​swinger|Swinger Operations]]
  
 +  * [[http://​inpp.ohio.edu/​~carterkde|DAQ instructions www.daqlinux.com]]
  
 +===== Tritium Operations =====
  
 +  * {{:​playground:​tritiumsop.pdf|Tritium SOP}}
 ===== Facility Shutdown ===== ===== Facility Shutdown =====
  
Line 104: Line 111:
   * [[playground:​vesda|VESDA]]   * [[playground:​vesda|VESDA]]
  
 +===== Emergency Responder Access =====
  
 + * {{emergency_entry_sop.pdf|Emergency Response Access SOP}}
  
  
 ===== Power Failures ===== ===== Power Failures =====
  
-        * [[playground:​power|Short Interuption (<min)]] +        * [[playground:​power|Short Interuption (<min)]] 
-  * [[playground:​powerout|Long Interuption ( >min)]]+  * [[playground:​powerout|Long Interuption ( >min)]]
  
  
Line 118: Line 127:
  
 ===== Tritium Emergency ===== ===== Tritium Emergency =====
-    * [[http://​www.ohio.edu/​riskandsafety/​docs/​radiation/​RadManAppendix24.pdf|Radiation Safety Handbook, Appendix 24: Tritium Gas Cells]]+    * [[https://​www.ohio.edu/​riskandsafety/​docs/​RadManual/​RadManAppendix24.pdf|Radiation Safety Handbook, Appendix 24: Tritium Gas Cells]]
     * [[playground:​tritium_emergency|Tritium Emergency Procedure]] (local copy, use RSH above as definitive copy)     * [[playground:​tritium_emergency|Tritium Emergency Procedure]] (local copy, use RSH above as definitive copy)
   ​   ​
Line 142: Line 151:
  
 ====== TRAINING FLOW & DOCUMENTATION ====== ====== TRAINING FLOW & DOCUMENTATION ======
 +
  
  
Line 153: Line 163:
 ===== Ohio Administrative Code and OUAL Compliance Statements ===== ===== Ohio Administrative Code and OUAL Compliance Statements =====
  
-  * [[http://​www.odh.ohio.gov/​~/​media/​ODH/​ASSETS/​Files/​rules/​final/​37011-68/​37011-68-05f.ashx|OAC 3701:​1-68-05 ​ Industrial Particle Accelerators]] +  * [[http://​www.odh.ohio.gov/​~/​media/​ODH/​ASSETS/​Files/​rules/​final/3701_1/​37011-68/​37011-68-05f.ashx|OAC 3701:​1-68-05 ​ Industrial Particle Accelerators]] 
-  * [[http://​www.odh.ohio.gov/​~/​media/​ODH/​ASSETS/​Files/​rules/​final/​37011-68/​37011-68-05-apdx.ashx|OAC 3701:​1-68-05 ​ Appendix A]]+  * [[http://​www.odh.ohio.gov/​~/​media/​ODH/​ASSETS/​Files/​rules/​final/3701_1/​37011-68/​37011-68-05-apdx.ashx|OAC 3701:​1-68-05 ​ Appendix A]]
   * [[playground:​compliance|OUAL Compliance Statements]]   * [[playground:​compliance|OUAL Compliance Statements]]
-  *[[http://​www.odh.ohio.gov/​rules/​final/​37011-38.aspx|OAC 3701:1-38 General Radiation Protection Standards for Sources of Radiation]]+  *[[http://​www.odh.ohio.gov/​rules/​final/37011/​37011-38.aspx|OAC 3701:1-38 General Radiation Protection Standards for Sources of Radiation]]
  
  
Line 163: Line 173:
  
   * {{personnel_classifications.pdf|Accelerator Personnel Classifications}}   * {{personnel_classifications.pdf|Accelerator Personnel Classifications}}
 +
 +
  
  
Line 173: Line 185:
 ===== Key Holder Training Flow ===== ===== Key Holder Training Flow =====
  
-  * {{key_holder_training_flow.pdf|Checklist}}+  * {{key_holder_training_flow_new.pdf|Checklist}}
  
  
Line 187: Line 199:
  
  
 +===== Operator Training Web Pages =====
 +
 +
 +
 +*[[https://​inpp.ohio.edu/​~oual/​operators/​operators.php]]
  
  
Line 234: Line 251:
  
  
-===== Operator Training Web Pages ===== 
- 
-*[[https://​edwards1.phy.ohiou.edu/​~oual/​operators/​training/​optrain.php]] 
  
  
start.txt · Last modified: 2023/09/08 13:06 by carter