This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
start [2012/03/12 17:06] jacobs |
start [2021/03/23 14:44] leblanc |
||
---|---|---|---|
Line 11: | Line 11: | ||
* [[playground:shift|Shift Change Procedure]] | * [[playground:shift|Shift Change Procedure]] | ||
+ | * [[http://apps.brownbearsw.com/iobee/OUAL/showview/-Default-|Update Lab IN/OUT Board]] | ||
- | ===== Manning the Control Console ===== | + | |
+ | |||
+ | ===== Staffing the Control Console ===== | ||
* [[playground:console|Console Policy]] | * [[playground:console|Console Policy]] | ||
+ | |||
+ | ===== Direct Reading Dosimeter (DRD) ===== | ||
+ | |||
+ | * [[playground:drd|DRD Instructions]] | ||
Line 26: | Line 33: | ||
===== General Safe Operating Procedures ===== | ===== General Safe Operating Procedures ===== | ||
- | * [[http://www.ohio.edu/riskandsafety/radiationsafety/rad_saf_handbook.htm#Htoc|See Sections III, IV, V, VI, and IX of the Radiation Safety Handbook]] | + | * [[https://www.ohio.edu/facilities/safety/radiation-safety/rad-saf-handbook|See Sections III, IV, V, VI, and IX of the Radiation Safety Handbook]] |
===== Source Instructions ===== | ===== Source Instructions ===== | ||
- | * [[playground:alpha|Alpha Source]] | + | * [[playground:alphatross|Alpha Source]] |
+ | * {{sourcehead.pdf|Alphatross Source Head Drawing}} | ||
* [[playground:sputter|Sputter Source]] | * [[playground:sputter|Sputter Source]] | ||
* [[sputter:pellet|Sputter Source Target Pellet Change]] | * [[sputter:pellet|Sputter Source Target Pellet Change]] | ||
+ | * [[playground:alpha|Old HVEC Alpha Source]] | ||
Line 43: | Line 52: | ||
* [[playground:trip|Over Voltage Trip]] | * [[playground:trip|Over Voltage Trip]] | ||
* [[playground:spark|Spark Instructions]] | * [[playground:spark|Spark Instructions]] | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
Line 60: | Line 76: | ||
===== Beam Operations ===== | ===== Beam Operations ===== | ||
+ | |||
+ | * {{inflectioncal.pdf|Inflection Magnet Curve (AMU*KeV vs. AMPs)}} | ||
* {{buncher_tables.pdf|Buncher/Extractor Tables}} | * {{buncher_tables.pdf|Buncher/Extractor Tables}} | ||
+ | * {{charge exchange.pdf|Charge State Yield Tables}} | ||
* [[playground:pulsing|Pulsing and Bunching]] | * [[playground:pulsing|Pulsing and Bunching]] | ||
- | * [[playground:quads|Computer Control of Quadrupoles]] | + | * [[playground:quadControls|Computer Control of Quadrupoles]] |
* [[playground:changeleg|Changing Legs]] | * [[playground:changeleg|Changing Legs]] | ||
* [[playground:nmr|NMR Setup]] | * [[playground:nmr|NMR Setup]] | ||
* [[playground:integrator|Beam Current Integrator]] | * [[playground:integrator|Beam Current Integrator]] | ||
+ | * [[playground:45R|Venting/Shutdown/Regenerate the 45R Beam Line]] | ||
+ | * Beam Energy: E = Terminal(charge state + 1) + injection energy | ||
+ | |||
+ | * Slits and Energy Resolution: dE/E = 2(dR/R) ! R = 28", dR is aperture size (each slit is 1/2 dR) | ||
+ | * [[playground:swinger|Swinger Operations]] | ||
+ | |||
+ | * [[https://inpp.ohio.edu/~daqlinux/index.html|DAQ instructions www.daqlinux.com]] | ||
+ | |||
+ | ===== Tritium Operations ===== | ||
+ | * {{:playground:tritiumsop.pdf|Tritium SOP}} | ||
===== Facility Shutdown ===== | ===== Facility Shutdown ===== | ||
Line 85: | Line 114: | ||
* [[playground:vesda|VESDA]] | * [[playground:vesda|VESDA]] | ||
+ | ===== Emergency Responder Access ===== | ||
+ | * {{emergency_entry_sop.pdf|Emergency Response Access SOP}} | ||
===== Power Failures ===== | ===== Power Failures ===== | ||
- | * [[playground:power|Short Interuption (<1 min)]] | + | * [[playground:power|Short Interuption (<3 min)]] |
- | * [[playground:powerout|Long Interuption ( >1 min)]] | + | * [[playground:powerout|Long Interuption ( >3 min)]] |
===== Chemical & Radiation Emergencies ===== | ===== Chemical & Radiation Emergencies ===== | ||
- | * [[http://www.ohio.edu/riskandsafety/radiationsafety/rad_saf_handbook.htm#Htoc|See Section VIII of the Radiation Safety Handbook]] | + | * [[https://www.ohio.edu/facilities/safety/radiation-safety/rad-saf-handbook|See Section VIII of the Radiation Safety Handbook]] |
===== Tritium Emergency ===== | ===== Tritium Emergency ===== | ||
- | * [[http://www.ohio.edu/riskandsafety/docs/radiation/RadManAppendix24.pdf|Radiation Safety Handbook, Appendix 24: Tritium Gas Cells]] | + | * [[https://www.ohio.edu/sites/default/files/sites/facilities/RadManAppendix24.pdf|Radiation Safety Handbook, Appendix 24: Tritium Gas Cells]] |
* [[playground:tritium_emergency|Tritium Emergency Procedure]] (local copy, use RSH above as definitive copy) | * [[playground:tritium_emergency|Tritium Emergency Procedure]] (local copy, use RSH above as definitive copy) | ||
| | ||
Line 123: | Line 154: | ||
====== TRAINING FLOW & DOCUMENTATION ====== | ====== TRAINING FLOW & DOCUMENTATION ====== | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
Line 129: | Line 166: | ||
===== Ohio Administrative Code and OUAL Compliance Statements ===== | ===== Ohio Administrative Code and OUAL Compliance Statements ===== | ||
- | * [[http://www.odh.ohio.gov/ASSETS/0CD47DC53BEB41B78B0DB8A6E2D7248B/Fr66_17.PDF|OAC 3701:1-66-17 Industrial Particle Accelerator]] | + | * [[http://codes.ohio.gov/oac/3701:1-68-02|OAC 3701:1-68-02 General requirements]] |
+ | * [[http://codes.ohio.gov/oac/3701:1-68-05v1|OAC 3701:1-68-05 Non-medical particle accelerator systems]] | ||
* [[playground:compliance|OUAL Compliance Statements]] | * [[playground:compliance|OUAL Compliance Statements]] | ||
- | *[[http://www.odh.ohio.gov/rules/final/f3701-1-38.aspx|OAC 3701:1-38 General Radiation Protection Standards for Sources of Radiation]] | + | *[[http://codes.ohio.gov/oac/3701%3A1-38|OAC 3701:1-38 General Radiation Protection Standards for Sources of Radiation]] |
Line 138: | Line 176: | ||
* {{personnel_classifications.pdf|Accelerator Personnel Classifications}} | * {{personnel_classifications.pdf|Accelerator Personnel Classifications}} | ||
+ | |||
+ | |||
Line 148: | Line 188: | ||
===== Key Holder Training Flow ===== | ===== Key Holder Training Flow ===== | ||
- | * {{key_holder_training_flow.pdf|Checklist}} | + | * {{key_holder_training_flow_new.pdf|Checklist}} |
Line 161: | Line 201: | ||
* {{operator_2_training_flow.pdf|Checklist}} | * {{operator_2_training_flow.pdf|Checklist}} | ||
+ | |||
+ | ===== Operator Training Web Pages ===== | ||
+ | |||
+ | |||
+ | |||
+ | *[[https://inpp.ohio.edu/~oual/operators/operators.php]] | ||
Line 167: | Line 213: | ||
====== Resource Materials ====== | ====== Resource Materials ====== | ||
+ | |||
+ | ===== Lab Layout ===== | ||
+ | |||
+ | *[[Lab Layout]] | ||
===== OUAL Tandem Accelerator ===== | ===== OUAL Tandem Accelerator ===== | ||
Line 182: | Line 232: | ||
* [[playground:grid|Gridded Lenses]] | * [[playground:grid|Gridded Lenses]] | ||
* [[playground:steerers|Electrostatic Steerers]] | * [[playground:steerers|Electrostatic Steerers]] | ||
+ | |||
===== Magnets ===== | ===== Magnets ===== | ||
Line 189: | Line 240: | ||
[[playground:quads|Quadrupoles]] | [[playground:quads|Quadrupoles]] | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | ===== Beam Measurement ===== | ||
+ | |||
+ | |||
+ | * [[Faraday Cups]] | ||
+ | * [[Current Meters]] | ||
+ | * [[Beam Profile Monitors]] | ||
+ | * [[Beam Pick Off]] | ||
+ | * [[playground:integrator|Beam Current Integrator (from the Beam Operations Section of the Operating Proceedures Book)]] | ||
+ | |||
+ | |||
+ | ===== Videos ===== | ||
+ | |||
+ | * [[https://inpp.ohio.edu/~carter/videos/SourceArea.mp4 |Source Area Egress/Ingress (4 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/GammaDet.mp4 |Portable Survey Instruments - Gammas (8 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/NeutronDet.mp4 |Portable Survey Instruments - Neutrons (5 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/LabWater.mp4 |Making Distilled/De-ionized Water (5 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/Levels_of_Vacuum.mp4 |Levels of Vacuum (17 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/MeasurementDevices.mp4 |Measurement Devices for Vacuum (36 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/MechanicalPumpsLabTour.mp4 |Mechanical Pumps - Lab Tour (3 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/HighVacPumpsLabTour.mp4 |High Vacuum Pumps - Lab Tour (8 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/VacuumConnections.mp4 |Vacuum Connections (16 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/Valves.mp4 |Gate Valves and Valves (15 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/PelletChange.mp4 |Sputter Source Pellet Change (10 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/ControlCams.mp4 |Control Room Camera Station (3 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/AlphaStart.mp4 |Alpha Source Startup (22 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/AlphaStop.mp4 |Alpha Source Shutdown (3 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/SputterStart.mp4 |Sputter Source Startup (8 min)]] | ||
+ | * [[https://inpp.ohio.edu/~carter/videos/SputterStop.mp4 |Sputter Source Shutdown (3 min)]] | ||
+ | |||
+ | ===== Engineering Info ===== | ||
+ | * [[Training Info]] | ||
+ | * [[Reference Documents]] | ||
+ | * {{:ext_list_-_2020-01-29.pdf|Inspection List - PDF}} | ||
+ | * {{:ext_list_-_2020-01-29.xlsx|Inspection List - Excel}} | ||
+ | * {{::monthly_fire_and_safety_inspection_instructions.pdf|Inspection Instructions - PDF}} | ||
+ | * {{::monthly_fire_and_safety_inspection_instructions.docx|Inspection Instructions - Word}} |