User Tools

Site Tools


start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
start [2012/03/08 18:14]
jacobs
start [2016/09/19 09:55]
jacobs [Accelerator Personnel Classifications]
Line 13: Line 13:
  
  
-===== Manning ​the Control Console =====+ 
 + 
 +===== Staffing ​the Control Console =====
  
   * [[playground:​console|Console Policy]]   * [[playground:​console|Console Policy]]
 +
 +===== Direct Reading Dosimeter (DRD) =====
 +
 +  * [[playground:​drd|DRD Instructions]]
  
  
Line 43: Line 49:
  * [[playground:​trip|Over Voltage Trip]]  * [[playground:​trip|Over Voltage Trip]]
   * [[playground:​spark|Spark Instructions]]   * [[playground:​spark|Spark Instructions]]
 +
 +
 +
 +
 +
 +
 +
 +
 +
  
  
Line 58: Line 73:
 ===== Beam Operations ===== ===== Beam Operations =====
  
 +
 +  * {{inflection.pdf|Inflection Magnet Curve (AMU*KeV vs. AMPs)}}
   * {{buncher_tables.pdf|Buncher/​Extractor Tables}}   * {{buncher_tables.pdf|Buncher/​Extractor Tables}}
 +  * {{charge exchange.pdf|Charge State Yield Tables}}
  * [[playground:​pulsing|Pulsing and Bunching]]  * [[playground:​pulsing|Pulsing and Bunching]]
 +  * [[playground:​quadControls|Computer Control of Quadrupoles]]
   * [[playground:​changeleg|Changing Legs]]   * [[playground:​changeleg|Changing Legs]]
   * [[playground:​nmr|NMR Setup]]   * [[playground:​nmr|NMR Setup]]
-  * {{HVEC_NMR.pdf|Original HVEC NMR Manual. Main frequency adjustment control and tracking feature now obsolete. ​ See above new procedures.}} 
   * [[playground:​integrator|Beam Current Integrator]]   * [[playground:​integrator|Beam Current Integrator]]
 +  * [[playground:​45R|Venting/​Shutdown/​Regenerate the 45R Beam Line]]
 +  * Beam Energy: ​ E = Terminal(charge state + 1) + injection energy
 +
 +  * Slits and Energy Resolution: ​ dE/E = 2(dR/​R) ​   ! R = 28", dR is aperture size (each slit is 1/2 dR)
 +  * [[playground:​swinger|Swinger Operations]]
 +
 +  * [[http://​www.daqlinux.com|DAQ instructions www.daqlinux.com]]
  
 ===== Facility Shutdown ===== ===== Facility Shutdown =====
Line 97: Line 122:
  
 ===== Tritium Emergency ===== ===== Tritium Emergency =====
-    * [[http://​www.ohio.edu/​riskandsafety/​docs/​radiation/​RadManAppendix24.pdf|Radiation Safety Handbook, Appendix 24: Tritium Gas Cells]]+    * [[https://​www.ohio.edu/​riskandsafety/​docs/​RadManual/​RadManAppendix24.pdf|Radiation Safety Handbook, Appendix 24: Tritium Gas Cells]]
     * [[playground:​tritium_emergency|Tritium Emergency Procedure]] (local copy, use RSH above as definitive copy)     * [[playground:​tritium_emergency|Tritium Emergency Procedure]] (local copy, use RSH above as definitive copy)
   ​   ​
Line 121: Line 146:
  
 ====== TRAINING FLOW & DOCUMENTATION ====== ====== TRAINING FLOW & DOCUMENTATION ======
 +
 +
 +
 +
 +
 +
  
  
Line 127: Line 158:
 ===== Ohio Administrative Code and OUAL Compliance Statements ===== ===== Ohio Administrative Code and OUAL Compliance Statements =====
  
-  * [[http://​www.odh.ohio.gov/​ASSETS/​0CD47DC53BEB41B78B0DB8A6E2D7248B/Fr66_17.PDF|OAC 3701:1-66-17  ​Industrial Particle ​Accelerator]]+  * [[http://​www.odh.ohio.gov/​~/​media/​ODH/ASSETS/Files/rules/​final/​3701_1/​37011-68/​37011-68-05f.ashx|OAC 3701:1-68-05  ​Industrial Particle ​Accelerators]] 
 +  * [[http://​www.odh.ohio.gov/​~/​media/​ODH/​ASSETS/​Files/​rules/​final/​3701_1/​37011-68/​37011-68-05-apdx.ashx|OAC 3701:​1-68-05 ​ Appendix A]]
   * [[playground:​compliance|OUAL Compliance Statements]]   * [[playground:​compliance|OUAL Compliance Statements]]
-  *[[http://​www.odh.ohio.gov/​rules/​final/​f3701-1-38.aspx|OAC 3701:1-38 General Radiation Protection Standards for Sources of Radiation]]+  *[[http://​www.odh.ohio.gov/​rules/​final/​37011/37011-38.aspx|OAC 3701:1-38 General Radiation Protection Standards for Sources of Radiation]]
  
  
Line 135: Line 167:
 ===== Accelerator Personnel Classifications ===== ===== Accelerator Personnel Classifications =====
  
-  * {{personnel_classifications.pdf|Accelerator Personnel Classifications}}+  * {{personnel___classifications.pdf|Accelerator Personnel Classifications}} 
 + 
  
  
Line 146: Line 180:
 ===== Key Holder Training Flow ===== ===== Key Holder Training Flow =====
  
-  * {{key_holder_training_flow.pdf|Checklist}}+  * {{key_holder_training_flow_new.pdf|Checklist}} 
  
 ===== Operator 1 Training Flow ===== ===== Operator 1 Training Flow =====
Line 152: Line 187:
   * {{operator_1_training_flow.pdf|Checklist}}   * {{operator_1_training_flow.pdf|Checklist}}
  
 +
 +
 +===== Operator 2 Training Flow =====
 +
 +  * {{operator_2_training_flow.pdf|Checklist}}
 +
 +
 +
 +
 +
 +
 +
 +====== Resource Materials ======
 +
 +===== Lab Layout =====
 +
 +  *[[Lab Layout]]
 +
 +===== OUAL Tandem Accelerator =====
 +
 +  * [[playground:​structure|Tank,​ Tubes, & Column]]
 +  * [[playground:​stripping|Terminal Stripping]]
 +  * [[playground:​pelletron|Pelletron Theory, OUAL Installation]]
 +  * [[playground:​TPS control|Terminal Potential Stabilizer Function and Components]]
 +  * [[playground:​control modules|Panel Fronts and Labeling]]
 +
 +
 +===== Electrostatic Components =====
 +
 +  * [[playground:​Einzel|Einzel Lenses]]
 +  * [[playground:​grid|Gridded Lenses]]
 +  * [[playground:​steerers|Electrostatic Steerers]]
 +
 +
 +===== Magnets =====
 +
 +4 Bending Magnets: ​ Inflection, Analyzer, Switcher, and Swinger
 +
 +[[playground:​quads|Quadrupoles]]
 +
 +
 +
 +
 +
 +===== Beam Measurement =====
 +
 +
 +  * [[Faraday Cups]]
 +  * [[Current Meters]]
 +  * [[Beam Profile Monitors]]
 +  * [[Beam Pick Off]]
 +  * [[playground:​integrator|Beam Current Integrator (from the Beam Operations Section of the Operating Proceedures Book)]]
 +
 +
 +===== Operator Training Web Pages =====
 +
 +*[[https://​inpp.ohiou.edu/​~oual/​operators/​training/​optrain.php]]
  
  
start.txt · Last modified: 2023/09/08 13:06 by carter