6. Set the TERMINAL VOLTAGE Dial to the desired value. The dial is 2 turns per MV (set the dial to twice the GVM you want). You may have to add some upcharge after setting the dial. | 6. Set the TERMINAL VOLTAGE Dial to the desired value. The dial is 2 turns per MV (set the dial to twice the GVM you want). You may have to add some upcharge after setting the dial. | ||
- | 7. Turn the TERMINAL VOLTAGE dial to zero. | + | 7. Raise the CONTROL GAIN to 2-3 for low current beams, around 5 for high current beams. The system is now controlling in GVM mode. |
+ | 8. Make fine adjustments to the TERMINAL VOLTAGE Dial to reach exactly the desired GVM value. | ||
+ | |||
+ | 9. | ||