Line 7: Line 7:
 3. Turn the CONTROL GAIN to zero. 3. Turn the CONTROL GAIN to zero.
  
-4. Turn the CHARGING VOLTAGE ​dial down to 0.10+4. To go to a higher energy move the CORONA PROBE POSITION "​OUT"​ while raising ​the CHARGING VOLTAGE. ​ ​**__NEVER__** allow the GRID VOLTAGE to go more negative than -10 VDC during this operation.
  
-5. Switch CHAIN MOTORS ​to OFF.+5. To go to a lower energy move the CORONA PROBE POSITION "​IN"​ while lowering the CHARGING VOLTAGE. ​ **__NEVER__** allow the GRID VOLTAGE to go more negative than -10 VDC during this operation.
  
-6. Switch POWER SUPPLIES ​to OFF.+6. Set the TERMINAL VOLTAGE Dial to the desired value. The dial is 2 turns per MV (set the dial to twice the GVM you want). You may have to add some upcharge after setting the dial.
  
-7. Turn the TERMINAL VOLTAGE dial to zero.+7. Raise the CONTROL GAIN to 2-3 for low current beams, around 5 for high current beams. The system is now controlling in GVM mode.
  
 +8.      Make fine adjustments to the TERMINAL VOLTAGE Dial to reach exactly the desired GVM value.
 +
 +9.
  