Machine Shutdown
Machine Shutdown
- Log Machine settings, log radiation monitor tape if necessary.
- Switch stabilizer to “AUTO”
- Put cup in – when putting in L.E. cup at high terminal voltage be prepared to run belt charge down as terminal voltage will increase when the beam loading is removed.
- Switch stabilizer to “STANDBY”.
- Turn “GRIDDED VOLTAGE TUBE LENS” down.
- Monitor corona current while changing belt charge; do not run in (extend) the corona points when the terminal charge may become negative (i.e. with the plastic belt). Reverse current will damage the stabilizer circuit.
- Run belt charge down.
- Turn belt charge “OFF”.
- Turn drive motor “OFF”.
- Start Source shut down (all control room operations).
- Set steerers to zero and then to “OFF”.
- Run magnets and quadrupole lenses down (coarse to zero, fine to 500), then turn off (push the “power” button).
- Turn the beam profile monitor (BPM) to “OFF”
- Turn buncher and chopper power to “OFF”.
- Complete control room source shutdown and run low energy extension einzel lenses down.
- (Only for maintenance shutdown) Switch stabilizer to “OFF”.
- (Only for maintenance shutdown) Turn key switch “OFF”.
- Complete source shut down in vault.