Faraday Cups
Wikipedia description of a Faraday Cup
OUAL Faraday Cup Control Panel Photograph
- Each cup is contolled by one of the push buttons in the photo.
- The name of the cup operated by the button is always illuminated.
- When the cup is in, the red “in” light in the button is illuminated.
- When the cup is out, the green “out” light in the button is illuminated.
- Each time a button is pushed the cup will change to the other state, in or out.
- Placing the LE cup in the “out” position will sound an audible and visual warning throughout the facility.
- When the HIGH RAD MODE key switch is in the “ON” position there will be a 15 second delay between pushing the LE cup “out” button and:
- The cup lifting out of the beam path
- The green “out” light on the button illuminating
- We have 4 Faraday Cups for beam current optimization at critical points along the beam path.
- LE: Located after the Buncher Tubes and before the LE XY steerer.
- HE: Located at the exit of the Accelerator before Quad 1.
- Analyzer: Located after the Image Slits and before the Beam Pick Off.
- Swinger: Located under the steps, after the Analyzer and before Swinger Magnet 1.