| Line 55: | Line 55: | ||
| b. Slowly raise the CONTROL GAIN to 2-3 for low current beams, around 5 for high current beams. | b. Slowly raise the CONTROL GAIN to 2-3 for low current beams, around 5 for high current beams. | ||
| - | c. Make fine adjustments to the TERMINAL VOLTAGE Dial to reach exactly the desired GVM value. | + | c. Make fine adjustments to the TERMINAL VOLTAGE Dial to reach exactly the desired GVM value. Very fine adjustments to the terminal voltage can be made using the FINE control located coaxial to the BIAS CURRENT control with a full range of 1.5 KV. |
| d. Switch OVERVOLTAGE PROTECTION to ENABLE. | d. Switch OVERVOLTAGE PROTECTION to ENABLE. | ||
| Line 63: | Line 63: | ||
| **4. Beam Transport** | **4. Beam Transport** | ||
| - | a. Use the magnet predictor tool and set Quad 1 to the predicted value. | + | a. Use the magnet predictor tool and set Quad 1 to the predicted value. Do not make large abrupt changes to the Quad 1 current. |
| b. Tune beam and send it around the properly configured Analyzing Magnet. | b. Tune beam and send it around the properly configured Analyzing Magnet. | ||
| Line 75: | Line 75: | ||
| **5. Dipole Magnet Setup Instructions** | **5. Dipole Magnet Setup Instructions** | ||
| - | a. Confirm that the Heinzinger power supplies are powered | + | a. Confirm that the Heinzinger power supplies are powered |
| b. If not already visible on the control room computer screen, start the appropriate software GUI's using the " | b. If not already visible on the control room computer screen, start the appropriate software GUI's using the " | ||
| - | c. In the " | + | c. In the " |
| - | d. The polarity can be toggled using the " | + | d. Run the slider to the desired current. |
| - | + | ||
| - | e. Run the slider to the desired current. | + | |