-==== Machine Shutdown ====+==== Accelerator Shutdown ====
  
-** Machine Shutdown **+1. Switch OVERVOLTAGE PROTECTION to DISABLE.
  
-   - Log Machine settings, log radiation monitor tape if necessary. +2. Switch the control mode to GVM. 
-   - Switch stabilizer to "AUTO" + 
-   - Put cup in -- when putting in L.E.  cup at high terminal voltage be prepared to run belt charge down as terminal voltage will increase when the beam loading is removed. +3. Slowly turn the CONTROL GAIN to zero while watching the grid voltage.  If the grid voltage rises above -5 volts, reduce the CHARGING VOLTAGE to keep the grid voltage less than -5 volts, then continue reducing the CONTROL GAIN to zero. 
-   - Switch stabilizer to "STANDBY". + 
-   - Turn "GRIDDED VOLTAGE TUBE LENS" down. +4. Turn the CHARGING VOLTAGE dial down to 0.10 
-   - Monitor corona current while changing belt charge; do not run in (extend) the corona points when the terminal charge may become negative (i.e. with the plastic belt).  Reverse current will damage the stabilizer circuit.  + 
-   - Run belt charge down.   +5. Switch CHAIN MOTORS to OFF. 
-   - Turn belt charge "OFF". + 
-   - Turn drive motor "OFF". +6. Switch POWER SUPPLIES to OFF. 
-   - Start Source shut down (all control room operations). + 
-   - Set steerers to zero and then to "OFF". +7. Turn the TERMINAL VOLTAGE dial to zero.
-   - Run magnets and quadrupole lenses down (coarse to zero, fine to 500), then turn off (push the "power" button). +
-   - Turn the beam profile monitor (BPM) to "OFF" +
-   - Turn buncher and chopper power to "OFF". +
-   - Complete control room source shutdown and run low energy extension einzel lenses down. +
-   - //(Only for maintenance shutdown)// Switch stabilizer to "OFF". +
-   - //(Only for maintenance shutdown)// Turn key switch "OFF". +
-   - Complete source shut down in vault.+
  
  