playground:shutdown [2009/03/04 15:46] – external edit 127.0.0.1playground:shutdown [2026/06/25 16:12] (current) – external edit 127.0.0.1
Line 1: Line 1:
-==== Machine Shutdown ====+==== Accelerator Shutdown ====
  
-** Machine Shutdown **+1. Switch OVERVOLTAGE PROTECTION to DISABLE.
  
-   1. Log Machine settings, log radiation monitor tape if necessary. +2. Switch the control mode to GVM. 
-   2. Switch stabilizer to "AUTO" + 
-   3. Put cup in -- when putting in L.E.  cup at high terminal voltage be prepared to run belt charge down as terminal voltage will increase when the beam loading is removed. +3. Slowly turn the CONTROL GAIN to zero while watching the grid voltage.  If the grid voltage rises above -5 volts, reduce the CHARGING VOLTAGE to keep the grid voltage less than -5 volts, then continue reducing the CONTROL GAIN to zero. 
-   4. Switch stabilizer to "STANDBY". + 
-   5. Turn "GRIDDED VOLTAGE TUBE LENS"  down and then push the " button. +4. Turn the CHARGING VOLTAGE dial down to 0.10 
-   6. Run belt charge down. + 
-   7. Turn belt charge "OFF". +5. Switch CHAIN MOTORS to OFF. 
-   8. Turn drive motor "OFF". + 
-   9. Start Source shut down (all control room operations). +6. Switch POWER SUPPLIES to OFF. 
-  10. Set steerers to zero and the to "OFF". + 
-  11. Run magnets and quadrupole lenses down ( coarse to zero, fine to 500),  the punch the "power" button. +7. Turn the TERMINAL VOLTAGE dial to zero.
-  12. Turn the beam profile monitor  (BPM) to "STANDBY" +
-  13. Turn buncher and chopper power to "OFF". +
-  14. Run low energy extension (L.E. EXT.) einzel lens down. +
-  15. Switch stabilizer to "OFF". +
-  16. Turn key switch "OFF". +
-  17. Complete source shut down in vault.+
  
  
playground/shutdown.1236199615.txt.gz · Last modified: (external edit)