| - Switch OVERVOLTAGE PROTECTION to DISABLE. | - Switch OVERVOLTAGE PROTECTION to DISABLE. | ||
| - Switch the control mode to GVM. | - Switch the control mode to GVM. | ||
| - | - Turn the CONTROL GAIN to zero. | + | - Slowly turn the CONTROL GAIN to zero while watching the grid voltage. |
| - | - To go to a higher energy move the CORONA PROBE POSITION " | + | - To go to a higher energy move the CORONA PROBE POSITION " |
| - | - To go to a lower energy move the CORONA PROBE POSITION " | + | - To go to a lower energy move the CORONA PROBE POSITION " |
| - Set the TERMINAL VOLTAGE Dial to the desired value. The dial is 2 turns per MV (set the dial to twice the GVM you want). You may have to add some upcharge after setting the dial. | - Set the TERMINAL VOLTAGE Dial to the desired value. The dial is 2 turns per MV (set the dial to twice the GVM you want). You may have to add some upcharge after setting the dial. | ||
| - Raise the CONTROL GAIN to 2-3 for low current beams, around 5 for high current beams. The system is now controlling in GVM mode. | - Raise the CONTROL GAIN to 2-3 for low current beams, around 5 for high current beams. The system is now controlling in GVM mode. | ||