| Line 1: | Line 1: | ||
| - | ==== NEC Alphatross RF Source Instructions ==== | + | ====== NEC Alphatross RF Source Instructions ====== |
| - | + | ||
| - | THESE ARE DRAFT INSTRUCTIONS WRITTEN REMOTELY. | + | |
| - | ** __START UP__ ** | + | === START UP === |
| - | ** In the Vault ** | + | == In the Vault == |
| - | - LE Extension vacuum must be good as evidenced by Ion Gauge controller with orange displays on magnet. | ||
| - | - Source vacuum must be good as evidenced by Ion Gauge controller with blue displays in 19" rack. | ||
| - | - Unground alpha source and hang shepherd' | ||
| - | - Go around and unground sputter source, hang shepherd' | ||
| - | ** In the Control Room ** | + | - Verify LE Extension Vacuum - indicated by Ion Gauge controller with orange displays on magnet. |
| + | - Verify Source Vacuum - indicated Ion Gauge controller with blue displays in 19" rack. | ||
| + | - Unground alpha source and hang shepherd' | ||
| + | - Close Alphatross gate and verify interlocks OK by observing indicator light. | ||
| + | - Set buncher tube selector switch - see [[playground: | ||
| + | - Unground sputter source [optional], hang shepherd' | ||
| + | - Close Sputter source gate. | ||
| - | | + | == In the Control Room == |
| + | |||
| + | | ||
| - To gain control of the source camera: On the joystick unit press " | - To gain control of the source camera: On the joystick unit press " | ||
| - | - Use the joystick and " | + | - Use the joystick and " |
| - | - If not already present, launch the Alphatross software on the source computer. | + | - If not already present, launch the Alphatross software |
| - | - In prompt succession press the " | + | - Press the " |
| + | - operates independently of the source and the HV interlocks. | ||
| + | - contains a flow switch that must be closed in order to start the source. | ||
| + | - provides heat to prevent Rb freezing. | ||
| + | - provides cooling to the magnet in the source. | ||
| + | - In prompt succession press the " | ||
| - These actions start a 60 second timer on the RF supply and set initial conditions on the Magnet and Mass Flow Controller. | - These actions start a 60 second timer on the RF supply and set initial conditions on the Magnet and Mass Flow Controller. | ||
| - | - After 60 seconds the RF power starts, gives a reading on the meter above the faraday | + | |
| - | - Plasma or not, raise the Magnet to 4 A, maybe the plasma | + | |
| - | - Monitor | + | - gives a reading on the meter above the Faraday |
| - | - Raise the Probe Voltage to 3 KV as a start, this might be enough | + | - may ignite |
| - | - If there is still no plasma try raising the Mass Flow setting | + | - Raise the Magnet |
| - | - Monitor the Probe Current, maintain 3 mA +/- 1 mA, and continue raising the Probe Voltage until it reaches 6.5 KV. | + | - If the plasma has not ignited |
| - | - Set the Oven Voltage to 87 V, wait ten minutes. | + | - Raise the gas flow until the plasma |
| - | - Set the Extractor Voltage to 5.5 KV and the Bias Voltage to a value that gives the desired injection energy | + | - Quickly lower the gas flow back to 0.350 SCCM (or your desired operating rate). |
| - | - You may now be able to look at negative beam in the source faraday | + | - Set the probe voltage by: |
| - | - Beam yield will increase as Mass Flow is reduced, expect optimum yield at //around// .2 SCCM. | + | - Monitoring |
| - | - Optimize negative | + | - it should remain less than 4 x 10-6 Torr. |
| - | - Use software buttons to take out faraday | + | - Operating range is around 2 x 10-6 or less. |
| - | - Set Lens A to 10 KV and source Einzel Lens to 15 KV initially and use the inflection magnet to pass beam on to the LE faraday cup. | + | - Raise the Probe Voltage to 3 kV. |
| - | - You may need to re-tune with Extractor, Bias, and Focus Voltages and Mass Flow setting. Each voltage tune will affect | + | - Check probe current |
| + | - Continue | ||
| + | - Maintain probe current less than 4mA. High probe current may indicate: | ||
| + | - Source is still grounded. | ||
| + | - Source is dirty and requires service. | ||
| + | - Set the Oven Voltage to 80 V. | ||
| + | - Set Extractor Voltage to 5kV. | ||
| + | - Set Bias Voltage to a value that gives desired injection energy. | ||
| + | - Injection energy is displayed in the upper window. | ||
| + | - Injection | ||
| + | - Beam yields improve | ||
| + | - Set the Focus Voltage to 5.5 kV | ||
| + | - Set the Faraday | ||
| + | - Tune for maximum __stable__ beam. | ||
| + | - Primary adjustment at this stage seems to be focus voltage. | ||
| + | - Current may be on the order of 30 μA. | ||
| + | - Set Einzel Lens to 20 kV. | ||
| + | - Wait until the Oven Temperature | ||
| + | - Tune for maximum stable | ||
| + | - Focus Voltage | ||
| + | - Mass Flow - optimum around 0.25 SCCM. | ||
| + | - Verify | ||
| + | - Open source gate valve. | ||
| + | - Take our source Faraday | ||
| + | - Move FC selector switch | ||
| + | - Tune beam into FC | ||
| + | - Set inflection magnet | ||
| + | - Typical beam currents at this stage are around 500 nA. | ||
| + | |||
| + | * Oven Voltage can be increased | ||
| + | |||
| + | ===SHUT DOWN=== | ||
| + | |||
| + | - Click the software button " | ||
| + | - Confirm you wish to quit by answering " | ||
| + | | ||
| + | - ** Do not open the source gates until the process is finished ** | ||
| + | - This process puts in the cup, closes the gate valve, and shuts down the source as things cool to proper levels. | ||
| + | - The automated process can be stopped by clicking | ||